10 | thermoIMAGER TIM10 | thermoIMAGER TIM
The right optics for many applications
1
Note: The accuracy of measurement can be outside of the specifications for distances below 0.2m.
2
Note: The accuracy of measurement can be outside of the specifications for distances below 0.5m.
Objective 72° x 52°; 95° wide angle; focal distance 3.3mm; min measuring distance 0.02m
1
HFOV
m 0.029 0.15 0.29 0.44 0.73 1.45 2.91 5.81 8.72 14.5 43.6 145.3
VFOV
m 0.020 0.10 0.20 0.29 0.49 0.98 1.95 3.90 5.85 9.8 29.3 97.5
DFOV
m 0.043 0.22 0.43 0.65 1.09 2.17 4.34 8.68 13.02 21.7 65.1 217.0
IFOV
mm 0.182 0.91 1.82 2.72 4.54 9.08 18.16 36.33 54.49 90.8 272.5 908.2
Distance in m 0.02 0.1 0.2 0.3 0.5 1 2 4 6 10 30 100
Objective 48° x 31°; 52° wide angle; focal distance 5.7mm; min measuring distance 0.02m
1
HFOV
m 0.015 0.08 0.15 0.23 0.38 0.76 1.51 3.02 4.53 7.6 22.7 75.6
VFOV
m 0.011 0.05 0.11 0.16 0.27 0.55 1.09 2.19 3.28 5.5 16.4 54.7
DFOV
m 0.019 0.10 0.19 0.29 0.49 0.97 1.95 3.90 5.85 9.7 29.2 97.5
IFOV
mm 0.094 0.47 0.94 1.42 2.36 4.72 9.45 18.89 28.34 47.2 41.7 472.3
Distance in m 0.02 0.1 0.2 0.3 0.5 1 2 4 6 10 30 100
Objective 23° x 17°; 29° standard; focal distance 10mm; min measuring distance 0.02m
1
HFOV
m 0.008 0.04 0.08 0.12 0.20 0.40 0.81 1.61 2.42 4.0 12.1 40.3
VFOV
m 0.006 0.03 0.06 0.09 0.15 0.30 0.60 1.20 1.79 3.0 9.0 29.9
DFOV
m 0.010 0.05 0.10 0.15 0.26 0.51 1.02 2.04 3.06 5.1 15.3 51.1
IFOV
mm 0.050 0.25 0.50 0.76 1.26 2.52 5.04 10.08 15.12 25.2 75.6 252.0
Distance in m 0.02 0.1 0.2 0.3 0.5 1 2 4 6 10 30 100
Objective 6° x 5°; 8° tele; focal distance 35.5mm; min measuring distance 0.5m
2
HFOV
m
-
- - - 0.06 0.11 0.23 0.45 0.68 1.1 3.4 11.3
VFOV
m - - - - 0.04 0.08 0.17 0.34 0.50 0.8 2.5 8.4
DFOV
m - - - - 0.07 0.14 0.28 0.56 0.84 1.4 4.2 14.1
IFOV
mm - - - - 0.35 0.71 1.41 2.82 4.23 7.1 21.2 70.5
Distance in m 0.02 0.1 0.2 0.3 0.5 1 2 4 6 10 30 100
FOV = Field of view; HFOV = Horizontal field of view; VFOV = Vertical field of view;
DFOV = Diagonal dimension of the total measuring field at the object level; IFOV = Indicated field of view
Objective 62° x 49°; 74° wide angle; focal distance 8mm; min measuring distance 0.02m
1
HFOV
m 0.024 0.12 0.24 0.36 0.60 1.20 2.40 4.80 7.20 12.0 36.0 119.9
VFOV
m 0.018 0.09 0.18 0.27 0.45 0.90 1.80 3.60 5.41 9.0 27.0 90.1
DFOV
m 0.030 0.15 0.30 0.45 0.75 1.50 3.00 6.00 8.99 15.0 45.0 149.9
IFOV
mm 0.063 0.31 0.63 0.94 1.57 3.14 6.28 12.56 18.84 31.4 94.2 314.0
Distance in m 0.02 0.1 0.2 0.3 0.5 1 2 4 6 10 30 100
Objective 38° x 29°; 49° standard; focal distance 15mm; min measuring distance 0.02m
1
HFOV
m 0.014 0.07 0.14 0.21 0.35 0.69 1.39 2.77 4.16 6.9 20.8 69.3
VFOV
m 0.010 0.05 0.10 0.15 0.25 0.51 1.02 2.03 3.05 5.1 15.2 50.8
DFOV
m 0.018 0.09 0.18 0.28 0.46 0.92 1.84 3.68 5.52 9.2 27.6 92.0
IFOV
mm 0.036 0.18 0.36 0.54 0.91 1.81 3.63 7.25 10.88 18.1 54.4 181.3
Distance in m 0.02 0.1 0.2 0.3 0.5 1 2 4 6 10 30 100
Objective 13° x 10°; 17° tele; focal distance 41mm; min measuring distance 0.5m
2
HFOV
m - - - - 0.12 0.23 0.47 0.94 1.40 2.3 7.0 23.4
VFOV
m - - - - 0.09 0.17 0.35 0.70 1.05 1.7 5.2 17.5
DFOV
m - - - - 0.15 0.29 0.58 1.17 1.75 2.9 8.8 29.2
IFOV
mm - - - - 0.31 0.61 1.22 2.45 3.67 6.1 18.4 61.2
Distance in m 0.02 0.1 0.2 0.3 0.5 1 2 4 6 10 30 100
FOV = Field of view; HFOV = Horizontal field of view; VFOV = Vertical field of view;
DFOV = Diagonal dimension of the total measuring field at the object level; IFOV = Indicated field of view
thermoIMAGER TIM 400/450
thermoIMAGER TIM 160/200/230
Precise measurement values can be calculated on
www.micro-epsilon.com/optikkalkulator
Standard-, tele- and wide angle
lens for different applications
High quality germanium len-
ses and a special antireflective
coating
Factory calibrated lenses
allowing the easy exchange of
optics without recalibration
HFOV
IFOV
DFOV
VFOV