thermoIMAGER TIM 14
2.1.2. Temperature Unit
When setting the Temperature unit you can choose between Celsius (°C) and
Fahrenheit (°F).
2.1.3. Temperature Range of Reference Bar
Via Min. and Max. settings you can allocate colors to temperature values within the
reference bar .
These are the following options:
Manual The upper and the lower border can be determined individually.
</>
The software continuously
defines the upper and the lower border based on the hottest and
coldest pixel in the image.
1 σ
The mean value of all pixels in the image will be continuously
calculated. Based on the mean
value one standard deviation (1 sigma) sets the limits of reference bar.
3 σ
The mean value of all pixels in the image will be continuously
calculated. Based on the mean
value three standard deviations (3 sigma) set the limits of reference bar.