2.5. Imager Interfaces
2.5.1. General
The TIM is equipped with a process interface (cable with integrated electronics and terminal block), which can
be programmed via the software as an Analog Input (AI) and Digital Input (DI) in order to control the camera or
as an Analog Output (AO) in order to control the process. The signal level is always 0 -10 V. The process
interface can be activated choosing the following options:
Analog Input (AI): Emissivity, ambient temperature, reference temperature, flag control, triggered
recording, triggered snapshots, triggered linescanner, uncommitted value
Analog Output (AO): Main area temperature, internal temperature, flag status, alarm, failsafe
Digital Input (DI): flag control, triggered recording, triggered snapshots, triggered linescanner
Configuration Process Interface (PIF)