12
Dependence between field of view (FOV)
and distance (lens 23° x 17°)
Plug&Play thermal imager
Powered from just one USB cable, the
system is truly plug and play. Data is
streaming from the camera to the soft-
ware via USB 2.0. in real time. This pro-
cess and analysis tool, provided with
every camera, enables the user to cap-
ture, record and monitor real time ther-
mal process images at 120 / 128Hz. The
software will store the data to a file, which
allows playback at user defined speeds,
e.g. in slow motion, frame by frame if
required. The image can be viewed and
monitored either online with the came-
ra connected, or off line at a later time
without the camera being connected. A
perfect tool for R&D applications, failure
diagnostics or process monitoring.
Additionally the software can be used as
a runtime application where the user is
able to program and configure a custom
environment. (multiple monitoring win-
dows, alarms, hot spot localization, line
profilen etc.) A programmable process
Interface, hard wired input and output,
(PIF in) enables external control and
communication for the emissivity of the
target material, trigger functions, shutter
control or alarm outputs and other useful
features.
The right optics for many applications
- Standard-, tele- and wide angle lens
for different applications
- High quality germanium lenses and a
special antireflective coating
- Factory calibrated lenses allowing the
easy exchange of optics without
recalibration
thermoIMAGER TIM 160/200: optics
Objective 48° x 37° wide angle; focal distance 4.5 mm; min distance 0.02m
HFOV
m
0.09 0.27 0.44 1.07 1.78 3.56 5.3 8.9 26.7 88.9
VFOV
m
0.07 0.20 0.33 0.80 1.33 2.67 4.0 6.7 20.0 66.7
IFOV
mm
0.56 1.67 2.78 6.67 11.11 22.22 33.3 55.6 166.7 555.6
Distance in m 0.1 0.3 0.5 1.2 2 4 6 10 30 100
Objective 23° x 17° wide angle; focal distance 10 mm; min distance 0.02m
HFOV
m
0.04 0.12 0.20 0.48 0.80 1.60 2.40 4.00 12.00 40.00
VFOV
m
0.03 0.09 0.15 0.36 0.60 1.20 1.80 3.00 9.00 30.00
IFOV
mm
0.25 0.75 1.25 3.00 5.00 10.00 15.00 25.00 75.00 250.00
Distance in m 0.1 0.3 0.5 1.2 2 4 6 10 30 100
Objective 6° x 5° wide angle; focal distance 35.5 mm; min distance 0.5m
HFOV
m
-
- 0.06 0.14 0.23 0.45 0.7 1.1 3.4 11.3
VFOV
m
-
- 0.04 0.10 0.17 0.34 0.5 0.8 2.5 8.5
IFOV
mm
-
- 0.35 0.85 1.41 2.82 4.2 7.0 21.1 70.4
Distance in m 0.1 0.3 0.5 1.2 2 4 6 10 30 100
FOV = Field of view; HFOV = Horizontal field of view; VFOV = Vertical field of view; IFOV = Indicated field of view